Model vs model

Premium vs mid-range vs value: Straumann BLX, Osstem TSIII and Implant Direct Legacy

One everyday implant from each price level, so you can see what actually differs.

The main differences
  • Price level differs. Straumann BLX: premium (€€€) · Osstem TSIII: mid-range (€€) · Implant Direct Legacy: value (€).
  • They come from different countries. Straumann BLX: 🇨🇭 Switzerland · Osstem TSIII: 🇰🇷 South Korea · Implant Direct Legacy: 🇺🇸 United States.
  • Different materials. Straumann BLX: Titanium–13 zirconium alloy (Roxolid®) · Osstem TSIII: Commercially pure titanium grade 4 · Implant Direct Legacy: not verified.
Highlighted rows differ.
AttributeStraumann BLX€€€ PremiumGet a quoteOsstem TSIII€€€ Mid-rangeGet a quoteImplant Direct Legacy€€€ ValueGet a quote
At a glance
BrandStraumannOsstemImplant Direct
Brand country🇨🇭 Switzerland🇰🇷 South Korea🇺🇸 United States
Price level€€€ Premium€€€ Mid-range€€€ Value
TypeEveryday bone-level implantEveryday bone-level implantEveryday bone-level implant
Designed forSituations where dentists often consider itImplants placed straight after a tooth is removed; Soft bone, where extra grip helpsEveryday single-tooth and bridge cases; Patients looking for a widely used mid-range implantEveryday cases at a value price level
Design
MaterialWhat the implant screw is made ofTitanium–13 zirconium alloy (Roxolid®)Commercially pure titanium grade 4Not verified
SurfaceHow the surface is treated so bone grows onSLActive® (hydrophilic) or SLA®SA (sand-blasted, acid-etched)Not verified
ConnectionHow the tooth part attachesTorcFit™ conical, 6 positionsInternal hexInternal hex with lead-in bevel
ShapeFully taperedTapered, self-tappingStraight top third, tapered lower two-thirds, buttress threads
DiametersHow thick the implant is3.5 – 6.5 mm3.5 – 6.8 mm (FDA range)3.2 mm
Lengths6 – 18 mm7 – 15 mmNot verified
Public record
FDA 510(k) clearanceYes: 3 records (e.g. K173961)Yes: 2 records (e.g. K121995)Yes: 2 records (e.g. K073033)
Good to know———

Design differences are not evidence that one implant gives better results. Your bone, your dentist's experience and your aftercare matter more. Specifications come from FDA 510(k) summaries and manufacturer documents. Open each model for sources.

Add another implant to this comparison →

Technical comparison for dentists (sourced specifications)
Comparison of Straumann BLX, Osstem TSIII
AttributeStraumann BLXOsstem TSIII
Overview
ManufacturerInstitut Straumann AGOsstem Implant Co., Ltd.
StatusCurrently marketedCurrently marketed
Implant type
Implant levelWhere the top of the implant sits: level with the bone, or higher up in the gum.
Bone level
Manufacturer-stated
Manufacturer documentation1 source · verified 27 Sept 2026
Submerged (bone-level) fixture
Regulatory record1 source · verified 27 Sept 2026
Body shapeThe overall shape of the screw that goes into the jaw.
Fully tapered body
Regulatory record1 source · verified 27 Sept 2026
Tapered body, self-tapping
Regulatory record2 sources · verified 27 Sept 2026
Material & surface
MaterialWhat the implant screw itself is made of.
Titanium–13 zirconium alloy (Roxolid®)
Regulatory recordManufacturer documentation2 sources · verified 27 Sept 2026
Commercially pure titanium, grade 4
Regulatory record2 sources · verified 27 Sept 2026
Material gradeNot verified
Grade 4 (ASTM F67 cited for the ultra-wide fixture)
Regulatory record1 source · verified 27 Sept 2026
SurfaceHow the outer surface is treated so bone can grow onto it.
SLActive® (hydrophilic) or SLA®
Manufacturer-stated
The 2024 technical document lists both SLActive and SLA article numbers. Market availability of each surface varies by country.
Manufacturer documentationRegulatory record2 sources · verified 27 Sept 2026
SA (sandblasted and acid-etched)
Other TSIII surface variants (e.g. CA, SOI) exist in some markets — research pending.
Regulatory record2 sources · verified 27 Sept 2026
Connection
ConnectionHow the visible tooth part (abutment) attaches to the implant.
TorcFit™ — conical connection with Torx-style engaging feature
Manufacturer documentationRegulatory record2 sources · verified 27 Sept 2026
Internal hex
Osstem describes a tapered (Morse-type) internal hex; taper angle not yet confirmed from an Osstem primary document.
Regulatory record2 sources · verified 27 Sept 2026
Connection angle
7° conical prosthetic connection (plus 22.5° shoulder on WB)
Manufacturer-stated
Manufacturer documentation1 source · verified 27 Sept 2026
Not verified
Anti-rotation index
6 positions (Torx-style)
Manufacturer-stated
Manufacturer documentation1 source · verified 27 Sept 2026
Not verified
Prosthetic platforms
RB (Regular Base, neck Ø3.5 mm) and WB (Wide Base, neck Ø4.5 mm); identical inner connection for all diameters
Manufacturer documentationRegulatory record2 sources · verified 27 Sept 2026
Not verified
Size range
DiametersHow thick the implant is. Your dentist chooses based on your bone.
Ø3.5, 3.75, 4.0, 4.5, 5.0, 5.5, 6.5 mm (endosteal)
Manufacturer-stated
Manufacturer documentation1 source · verified 27 Sept 2026
Range Ø3.5–6.8 mm across TS fixtures in the 2012 FDA summary (measured values; nominal catalogue diameters pending)
Regulatory record1 source · verified 27 Sept 2026
LengthsHow long the implant is. Shorter ones are used where there is less bone.
6, 8, 10, 12, 14, 16, 18 mm
Manufacturer-stated
Not every length exists in every diameter: 6 mm is not listed for Ø3.5; 18 mm is listed up to Ø5.0 only.
Manufacturer documentation1 source · verified 27 Sept 2026
7.0–15.0 mm (2012 FDA summary)
Regulatory record1 source · verified 27 Sept 2026
Macrogeometry
Thread design
Self-cutting threads; pitch 1.7–3.1 mm depending on diameter and length
Manufacturer-stated
Manufacturer documentation1 source · verified 27 Sept 2026
Not verified
Apex
2 or 4 apical cutting edges depending on diameter
Manufacturer-stated
Manufacturer documentation1 source · verified 27 Sept 2026
Not verified
Neck / collar
Neck height 1.0–2.0 mm with micro-threads (0.5–1.0 mm), varying by length
Manufacturer-stated
Manufacturer documentation1 source · verified 27 Sept 2026
Not verified
Indications
Immediate function (labeling)Whether a temporary tooth may be fitted on the same day, according to official labeling.
What the regulatory labeling permits. It is not evidence that immediate loading works better with this system.
US labeling: immediate function on single-tooth applications when good primary stability and appropriate occlusal loading are achieved
Labeling wording, not evidence of clinical superiority.
Regulatory record1 source · verified 27 Sept 2026
Not verified
Restrictions & cautions
Manufacturer advises particular care placing Ø3.5 mm implants in molar or other high-load situations
Manufacturer-stated
Manufacturer documentation1 source · verified 27 Sept 2026
Not verified
Surgical protocol
Max insertion torqueNot verifiedNot verified
Regulatory & safety
FDA 510(k) records linked5
earliest 5 Jun 2018
2
earliest 29 Nov 2012
FDA recall records foundNone found
openFDA search “BLX”, 27 Sept 2026. No result is not proof of no recall.
None found
openFDA search “TSIII”, 27 Sept 2026. No result is not proof of no recall.

Highlighted rows differ between systems. A difference in design or labeling is not evidence that one system gives better clinical results.

Free quote

Get prices for Straumann BLX and Osstem TSIII and Implant Direct Legacy

Tell us about your situation. We'll send a personalised plan with prices for these options, and alternatives, within 24 hours.

Which is better, Straumann BLX or Osstem TSIII or Implant Direct Legacy?
Neither is better for everyone. Straumann BLX is built for grip in soft bone and for same-day teeth; Osstem TSIII is the korean workhorse implant used in clinics worldwide; Implant Direct Legacy is value implant with a familiar internal-hex design. The right choice depends on your bone, your treatment plan, your budget and your dentist's experience with the system.
What is the price difference between Straumann BLX and Osstem TSIII and Implant Direct Legacy?
Straumann BLX is usually a premium (€€€) option; Osstem TSIII is usually a mid-range (€€) option; Implant Direct Legacy is usually a value (€) option. Actual prices depend on the clinic, country and what is included. Request a free quote to see both side by side for your case.
Can I ask my dentist to use a different brand?
Yes, you can ask. Many clinics offer several brands at different price levels. Ask why they recommend a particular system and whether they use it regularly.
Get your free Straumann / Osstem / Implant Direct implant quoteTakes about 60 seconds
What do you need?

Choose the closest option. You can explain more later.

How many teeth are missing or failing?
Which implant level interests you?

Not sure? Choose “advise me”. We'll explain the options.

When would you like treatment?
Where would you like to be treated?
Where should we send your quote?

Free and without obligation. We reply within 24 hours.

+ Add an x-ray, photo or existing quote (optional)
  • Free & no obligation
  • Reply within 24h
  • Your data stays private
Get my free implant quote →